NBD LABS ISRAEL PROFESSIONAL TOP SERVICE
NBD LABS ISRAEL PROFESSIONAL TOP SERVICE
NBD LABS ISRAEL PROFESSIONAL TOP SERVICE

PRODUCTS

CVD Atmosphere Tube Furnace NBD-O1200-60IT150-D3F

product introduction:

1200℃ CVD vacuum tube furnace is widely used in kinds of CVD experiments which reaction temperature is round 1150 ℃. It is also used for vacuum sintering, vacuum sintering under atmosphere protection, nano materials preparation, battery material preparation and other multiple research fields.

 

1200℃ CVD Atmosphere Tube Furnace is widely used in kinds of CVD experiments which reaction temperature is round 1150 ℃. It is also used for vacuum sintering, vacuum sintering under atmosphere protection, nano materials preparation, battery material preparation and other multiple research fields.

Main part of CVD Atmosphere Tube Furnace system

  1. 1200℃ single zone opentube furnace
  2. Three channel float flow meter
  3. NBD-4C vacuum pump

1200℃ single zone two channel gas CVD tube furnace system technical data:

1 Product name 1200℃ single zone three channel gas CVD system
2 model NBD-O1200-50IT150-D3F
3 NBD-O1200-60IT150-D3F
4 NBD-O1200-80IT150-D3F
5 NBD-O1200-100IT150-D3F
6 Chamber type Open
7 Displaying mode LED displaying
8 Chamber material Imported alumina fiber
9 Heating element imported alloy heating wire
10 Max. Temperature 1200℃
11 Working temperature ≤1150℃
12 Heating rate ≤20℃(adviced:10℃/min)
13 Heating zone single
14 Length of temperature zone 440mm
15 Length of constant temperature zone 220mm
16 Tube material High purity quartz
17 Tube diameter 50mm
18 60mm
19 80mm
20 100mm
21 Tube length 1000mm
22 Sealing method high vacuum stainless steel flange
23 Gas tightness Gas tightness of vacuum flange and quartz tube can reach to 4.03×10-3Pa.
24 Controlling mode smart PID multiple segments programmable controlling
25 Accuracy ±1℃
26 Temperature curve multiple segments“time-temperature curve”
27 Presetting curve 10pcs
28 Over temperature alarm yes
29 Over-current protection yes
30 broken thermocouple prompt yes
31 Thermocouple K type
32 Certification CE
33 voltage 220V 50Hz~60Hz
34 power 2.5KW
35 Gas channel three
36 Flow meter Float flow meter
37 A channel range 10~100ml/min
38 B channel range 16~160ml/min
39 C channel range 25~250ml/min
40 Pressure of gas channel -0.1~0.15 MPa
41 Vacuum degree 5~10Pa(If require other vacuum degree, it need to choose different vacuum device)
42 Connection of pump pipe KF16 stainless steel bellows, KF16 quick clamp,KF16 flapper valve
43 Vacuum gauge standard mechanical vacuum gauge, optional electronic vacuum gauge
44 Warranty 12 months limited warranty
45 Package Plywood case
46 Standard accessories Quartz tube, Vacuum Flange, Tube Block, O-ring, protective goves, crucible tongs, manual book, PTFE hose, stainless steel quick clamp,stainless steel bellows , KF adapter, 5mm  Allen wrench
47 Dimensions 700mmx600mmx1190mm