For equipment enquiries and technical assistance, email oremir15@outlook.com.
Equipment introduction:
Mini agitator sintering tube furnace is suitable for experimental equipment of heat treatment of various materials. The main industries are rare earth preparation, electronic lighting, crystal annealing, bioceramics, electronic ceramics, special alloys, magnetic materials, precision casting, etc., mainly used in vacuum sintering, atmosphere protection sintering, vacuum coating, CVD experiment, substance composition measurement and other occasions.
Equipment introduction:
Mini agitator sintering tube furnace is suitable for experimental equipment of heat treatment of various materials. The main industries are rare earth preparation, electronic lighting, crystal annealing, bioceramics, electronic ceramics, special alloys, magnetic materials, precision casting, etc., mainly used in vacuum sintering, atmosphere protection sintering, vacuum coating, CVD experiment, substance composition measurement and other occasions.
Configuration
1. Through constant rotation, the material can be heated and contact with the gas more fully and evenly; | |||||||
Model | NBD-RT1200-50TI | ||||||
Electrical Spec | AC220V 1.2KW | ||||||
Tmax | 1200 ℃ | ||||||
Max working temps. | 1150 ℃ | ||||||
Heating rate | ≤ 10 ℃/min | ||||||
Heating zone size | φ80*100mm | ||||||
Tube size | Φ50×220mm(One end is sealed ) | ||||||
Effective volume | 70ml (Tilt 90 degrees) 48ml (tilt 60 degrees) 33ml (Tilt 45 degrees) 17ml (Tilt 30 degrees) | Calculate the constant temperature zone according to the length of temperature zone 50 | |||||
control system |
| 1. 15 temperature curves can be pre-stored to avoid the trouble caused by repeated setting of different experimental processes; | |||||
Temp Accuracy | +/- 1 ℃ | ||||||
Heating element |
| Mo-doped Fe-Cr-Al alloy | |||||
Equipment details |
| ||||||
Vacuum degree: ≤10Pa (mechanical pump) | |||||||
Pressure measurement and monitoring |
| The mechanical pressure gauge with damping oil is used to produce damping when the pressure fluctuates and reduce the pointer to swing back and forth. | |||||
Net Weight | 20KG | ||||||
Operating Precautions | 1. Do not open the furnace chamber when its temperature is ≥300℃ to avoid injury. 2. During operation, tube pressure must not exceed 0.125MPa absolute to prevent damage from excessive pressure. 3. When operating under vacuum, the operating temperature must not exceed 800℃. 4. Gas cylinders contain high pressure. A pressure-reducing valve must be fitted to the cylinder when supplying gas to the furnace tube. A low-pressure regulator with a range of 0.01MPa-0.15MPa is recommended for more precise and safer experimental use. 5. When the furnace temperature exceeds 1000℃, the tube must not be under vacuum. Keep the tube at atmospheric pressure. 6. The long-term operating temperature of the high-purity quartz tube is ≦1100℃. 7. During heating experiments, closing both the exhaust and inlet valves at the tube flanges is not recommended. If the sample must be heated with the gas valves closed, continuously monitor the pressure gauge. If absolute pressure exceeds 0.15MPa, immediately open the exhaust valve to prevent accidents such as tube rupture or flange ejection. | ||||||
Service and Support | 1 year warranty with lifetime support (consumable components, such as furnace tubes and seals, are excluded). | ||||||