It is developed for analysing the weight loss by combustion and pyrolysis (TGA) of materials. It includes several parts, such as balance, heating furnace, programmed temperature control system, recording system, etc. It can observe the change of sample mass with temperature and time during the process of heating up, constant temperature or cooling down, and it is equipped with pyrolysis material condensation collection device. It is widely used in research and development, process optimisation and quality control in the fields of plastics, rubber, coatings, pharmaceuticals, catalysts, inorganic materials, metal materials and composites.
Introduction to Vacuum Atmosphere Circulating Annealing Furnace Equipment:
Equipment features: | ||||||||
Device Name | Quick annealing furnace | |||||||
Specification and model | NBD-CMT1200-60TI+ | |||||||
Power supply | single-phase220V 50HZ | |||||||
Rated power | 4KW | |||||||
| Number of temperature zones | Single temperature and single control | |||||||
| control accuracy | ±1℃ | |||||||
| Sensor type | K-type thermocoupleΦ1*500mm | |||||||
| maximum temperature | 1150℃ | |||||||
| Furnace tube material | quartzΦ60*1400mm | |||||||
| heating rate | 1℃/H-20℃/Min | |||||||
| Temperature zone size length | Φ150*430mm | |||||||
| Furnace body size | 1520 long x 520 high x 550mm deep | |||||||
| Heating element | High temperature resistance wire | |||||||
control system | ||||||||
stem | 1. Sintering process curve setting: dynamically display the setting curve, the equipment sintering can pre store multiple process curves, and each process curve can be freely set; | |||||||
Temperature accuracy | ±1℃ | |||||||
Heating element | Mo doped Fe Cr Al alloy | |||||||
Sealing system | ||||||||
Vacuum degree: 10Pa (mechanical pump) | ||||||||
Pressure measurement and monitoring | Using a mechanical pressure gauge, the outer shell of the gauge is an airtight structure, which can effectively protect the internal components from environmental impact and debris intrusion, and has strong corrosion and high temperature resistance. | |||||||
Gas supply system | The gas flow rate is controlled by a float flowmeter, integrated with the equipment, and leak testing has been carried out before leaving the factory. | |||||||
Net weight | 100kg | |||||||
Equipment usage precautions | 1. When the furnace temperature of the equipment is ≥ 300 ℃, it is prohibited to open the furnace to avoid injury; | |||||||
Service support | One year limited warranty with lifetime support (warranty does not include consumable parts such as handling pipes and O-rings. Please order replacement parts at the relevant product section below.) | |||||||
Disclaimer: The product introduction content on this website (including product images, product descriptions, technical parameters, etc.) is for reference only. Due to untimely updates, there may be some discrepancies between the described content and the actual situation. Please contact our customer service personnel for confirmation. The information provided on this website does not constitute any offer or commitment, and Novartis may periodically improve and modify any information on the website without prior notice.